How To Solve Table With Insufficient Suction

How to solve the insufficient suction of woodworking engraving machine platform?

In the use of woodworking engraving machines, there may be a phenomenon that the adsorption table has no suction and cannot absorb the board. What is the reason for this and how to solve it?
Today, I will introduce to you the solution to the non-adsorption of the woodworking engraving machine table:
1. Whether the motor line voltage is normal;
2. Whether the water circulating air pump has less water, whether the motor is stuck and rusted, and remove the motor fan protection net to rotate the axis;
3. Clean up the filter blockage in the vacuum pump;
4. Repair the countertop or pipeline for air leakage;
5. On the positive and negative switching motor, any two wires can change the direction of the motor.
The woodworking engraving machine adopts vacuum adsorption to fix the plate, which can not only be firmly fixed without moving and engraving dislocation, etc., but also fixed relative to the splint, which can save the plate and engrave to the edge of the plate, saving time and effort.